datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

IDT7008S 查看數據表(PDF) - Integrated Device Technology

零件编号
产品描述 (功能)
比赛名单
IDT7008S
IDT
Integrated Device Technology IDT
IDT7008S Datasheet PDF : 19 Pages
First Prev 11 12 13 14 15 16 17 18 19
IDT7008S/L
High-Speed 64K x 8 Dual-Port Static RAM
Truth Table V —Address BUSY
Arbitration(4)
Military, Industrial and Commercial Temperature Ranges
Inputs
Outputs
CEL CER
AOL-A15L
AOR-A15R
BUSYL(1) BUSYR(1)
Function
X
X
NO MATCH
H
H
No rmal
HX
MATCH
H
H
No rmal
X
H
MATCH
H
H
No rmal
L
L
MATCH
(2)
(2)
Write
Inhibit(3)
3198 tbl 17
NOTES:
1. Pins BUSYL and BUSYR are both outputs when the part is configured as a master. Both are inputs when configured as a slave. BUSY outputs on the IDT7008 are
push-pull, not open drain outputs. On slaves the BUSY input internally inhibits writes.
2. "L" if the inputs to the opposite port were stable prior to the address and enable inputs of this port. "H" if the inputs to the opposite port became stable after the address
and enable inputs of this port. If tAPS is not met, either BUSYL or BUSYR = LOW will result. BUSYL and BUSYR outputs can not be LOW simultaneously.
3. Writes to the left port are internally ignored when BUSYL outputs are driving LOW regardless of actual logic level on the pin. Writes to the right port are internally ignored
when BUSYR outputs are driving LOW regardless of actual logic level on the pin.
4. Refer to Chip Enable Truth Table.
Truth Table VI — Example of Semaphore Procurement Sequence(1,2,3)
Functions
D0 - D7 Left
D0 - D7 Right
Status
No Action
1
1
Semaphore free
Left Port Writes "0" to Semaphore
0
1
Left port has semaphore token
Right Port Writes "0" to Semaphore
0
1
No change. Right side has no write access to semaphore
Left Port Writes "1" to Semaphore
1
0
Right port obtains semaphore token
Left Port Writes "0" to Semaphore
1
0
No change. Left port has no write access to semaphore
Right Port Writes "1" to Semaphore
0
1
Left port obtains semaphore token
Left Port Writes "1" to Semaphore
1
1
Semaphore free
Right Port Writes "0" to Semaphore
1
0
Right port has semaphore token
Right Port Writes "1" to Semaphore
1
1
Semaphore free
Left Port Writes "0" to Semaphore
0
1
Left port has semaphore token
Left Port Writes "1" to Semaphore
1
1
Semaphore free
NOTES:
1. This table denotes a sequence of events for only one of the eight semaphores on the IDT7008.
2. There are eight semaphore flags written to via I/O0 and read from all I/O's (I/O0-I/O7). These eight semaphores are addressed by A0-A2.
3. CE = VIH, SEM = VIL to access the semaphores. Refer to the Semaphore Read/Write Control Truth Table.
3198 tbl 18
Functional Description
The IDT7008 provides two ports with separate control, address and
I/O pins that permit independent access for reads or writes to any location
in memory. The IDT7008 has an automatic power down feature controlled
by CE. The CE0 and CE1 control the on-chip power down circuitry that
permits the respective port to go into a standby mode when not selected
(CE HIGH). When a port is enabled, access to the entire memory array
is permitted.
Interrupts
If the user chooses the interrupt function, a memory location (mail box
or message center) is assigned to each port. The left port interrupt flag
(INTL) is asserted when the right port writes to memory location FFFE
(HEX), where a write is defined as CER = R/WR = VIL per the Truth Table.
The left port clears the interrupt through access of address location FFFE
when CEL = OEL = VIL, R/W is a "don't care". Likewise, the right port
interrupt flag (INTR) is asserted when the left port writes to memory location
FFFF (HEX) and to clear the interrupt flag (INTR), the right port must read
the memory location FFFF. The message (8 bits) at FFFE or FFFF is user-
defined since it is an addressable SRAM location. If the interrupt function
is not used, address locations FFFE and FFFF are not used as mail boxes,
but as part of the random access memory. Refer to Table IV for the interrupt
operation.
16