datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

LA76075 查看數據表(PDF) - SANYO -> Panasonic

零件编号
产品描述 (功能)
比赛名单
LA76075 Datasheet PDF : 35 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
LA76075
Item
[Chroma Block]
ACC amplitude
characteristic 1
ACC amplitude
characteristic 2
B-Y/Y amplitude ratio
Color control
characteristic 1
Color control
characteristic 2
Color control sensitivity
Tint center
Tint control maximum
Tint control minimum
Tint control sensitivity
Demodulator output R-
Y/B-Y ratio
Demodulator output G-
Y/B-Y ratio
Measurement
Symbol
Point
Input
Signal
Measurement Procedure
Bus Condition
ACCM1
ACCM2
CLRBY
CLRMN
CLRMM
CLRSE
TINCEN
TINMAX
TINMIN
TINSE
RB
GB
Bout
30
Bout
30
30
30
30
30
30
30
30
30
29
28
30
29
C-1
0 dB
+6 dB
Measure the outputs for chroma inputs of 0 dB and +6
dB and substitute in the following formula.
ACCM1 = 20log
(+6 dBdata/0 dBdata)
C-1
–14 dB
Measure the outputs for chroma inputs of 0 dB and -14
dB and substitute in the following formula.
ACCM1 = 20log
(–14 dBdata/0 dBdata)
YIN : L77
C-1 : No signal
Measure V1, the Y output level.
Next supply the CIN signal (with only the
C-2
synchronization signal for YIN), measure V2, the
output level, and substitute in the following formula.
CLRBY = 100 × (V2/V1) + 15%
C-3
Measure V1, the output amplitude (Vp-p) for the
maximum color control setting, and V2, the output
amplitude (Vp-p) for the medium one, and substitute in
the following formula.
CLRMN = V1/V2
Color.1111111
(MAX)
Color.1000000
(NOM)
Measure V3, the output amplitude (Vp-p) for minimum
C-3
color control setting, and substitute in the following Color.0000000
formula.
(MIN)
CLRMN = 20 log (V1–V3)
Measure V4, the output amplitude (V{p-p}) for a color
C-3
control setting of 90, and V5, the output amplitude (Vp-
p) for one of 38, and substitute in the following
formula.
Color.1011010
Color.0100110
CLRSM = 100 × (V4–V5) / (V2 × 52)
C-1
Measure the output waveform and calculate the B-Y
angle.
TINT : 1000000
Measure the output waveform, calculate the B-Y
C-1
angle, and substitute in the following formula.
TINT : 1111111
TINMAX = B-Y angle - TINCEN
Measure the output waveform, calculate the B-Y
C-1
angle, and substitute in the following formula.
TINT : 0000000
TINMIN = B-Y angle - TINCEN
Measure A1, the angle for a tint control setting of 85,
C-1
and A2, the angle for one of 42, and substitute in the TINT : 1010101
following formula.
TINT : 0101010
TINSE = (A1–A2)/43
Supply the L77 signal to the YIN pin and adjust the red
and blue drive digital-to-analog converters until the Y
YIN : L77
C-1 : No signal
YIN : 0RE
C-3
output levels at pins 28 (RED OUT) and 30 (BLU OUT)
are closest to that at pin 29 (GRN OUT).
1. After the above adjustment, supply 0 RE to the YIN
pin and C-3 to the CIN pin, measure Vb, the BOUT
output amplitude (Vp-p), and Vr, the ROUT output
amplitude (Vp-p), and substitute in the following
Color : 1000000
B Drive
R Drive
Adjusted red and blue
drive values.
formula.
RB = Vr/Vb
Measure Vg, the GOUT output amplitude (V{p-p}), and Color : 1000000
substitute in the following formula.
B Drive
C-3
GB = Vg/Vb
Use adjusted red and blue
Use the adjusted red and blue drive values from the drive values from the RB
RB determination above.
determination above.
Continued on next page.
No. 5845-19/35

Share Link: 