datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

LA76075 查看數據表(PDF) - SANYO -> Panasonic

零件编号
产品描述 (功能)
比赛名单
LA76075 Datasheet PDF : 35 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
LA76075
Continued from preceding page.
Measurement
Item
Symbol
Point
Demodulator angle B-Y/
30
ANGBR
R-Y
28
Demodulator angle G-Y/
ANGBG
29
B-Y
Killer operation point
KILL
30
Chroma VCO free run
frequency
CVCOF
42
Chroma pull-in range (+) PULIN+
30
Chroma pull-in range (–) PULIN–
30
30
Auto Flesh characteristic
73°
AF073
28
30
Auto Flesh characteristic
118°
AF118
28
30
Auto Flesh characteristic
163°
AF163
28
Overload characteristic 1 OVL1
28
Overload characteristic 2 OVL2
28
Overload characteristic 3 OVL3
28
fsc output amplitude
Vfsc
42
(Vp-p)
Input
Signal
C-1
C-1
C-3
CIN
No signal
C-1
C-1
C-4
C-4
C-4
C-5
C-5
C-5
C-1
Measurement Procedure
Bus Condition
Measure the BOUT and ROUT output levels, calculate
the B-Y and R-Y angles, and substitute in the following
formula.
ANGBR = R-Y angle - B-Y angle
Measure the GOUT output level, calculate the B-Y and
R-Y angles, and substitute in the following formula.
ANGBG = G-Y angle - B-Y angle
Gradually lower the input signal level and measure the
input level at which the output level falls below 150
mVp-p
Measure the oscillation frequency f and substitute in
the following formula.
CVCOF = f – 357945 (Hz)
Gradually lower the input signal subcarrier frequency
from 3.57545 MHz + 1000 Hz and measure the
frequency at which the output waveform locks.
Gradually raise the input signal subcarrier frequency
from 3.57545 MHz - 1000 Hz and measure the
frequency at which the output waveform locks.
Set AutoFlesh to “0,” measure the levels at the 73°
portions of the BOUT and ROUT output waveforms,
and calculate the angle AF073A. Set AutoFlesh to “1,” AutoFlesh : 0
repeat the procedure to determine AF073B, and AutoFlesh : 1
substitute in the following formula.
AF073 = AF073B – AF073A
Set AutoFlesh to “0,” measure the levels at the 118°
portions of the BOUT and ROUT output waveforms,
and calculate the angle AF118A. Set AutoFlesh to “1,” AutoFlesh : 0
repeat the procedure to determine AF118B, and AutoFlesh : 1
substitute in the following formula.
AF118 = AF118B – AF118A
Set AutoFlesh to “0,” measure the levels at the 163°
portions of the BOUT and ROUT output waveforms,
and calculate the angle AF163A. Set AutoFlesh to “1,” AutoFlesh : 0
repeat the procedure to determine AF163B, and AutoFlesh : 1
substitute in the following formula.
AF163 = AF163B – AF163A
Measure V1, the output amplitude (Vp-p) for an input
signal burst level of 40 IRE and a chroma level of 8
IRE, and V2, the same for a burst level of 40 IRE and
a chroma level of 40 IRE, and substitute in the
OverLoad : 1
following formula.
OVL1 = V2/V1
Measure V3, the output amplitude (Vp-p) for an input
signal burst level of 40 IRE and a chroma level of 80
IRE, and substitute in the following formula.
OverLoad : 1
OVL2 = V3/V1
Measure V4, the output amplitude (Vp-p) for an input
signal burst level of 20 IRE and a chroma level of 80
IRE, and substitute in the following formula.
OverLoad : 1
OVL3 = V4/V1
Measure the output amplitude (V{p-p}) of the 3.58-MHz
CW output at pin 42 (FSC OUT).
Continued on next page.
No. 5845-20/35

Share Link: 