MAX6006–MAX6009
1µA SOT23 Precision Shunt
Voltage Reference
Electrical Characteristics—MAX6009
(TA = -40°C to +85°C, unless otherwise noted. Typical values are at TA = +25°C.) (Note 1)
PARAMETER
Reverse Breakdown Voltage
Minimum Operating Current
Reverse Breakdown Change
with Current
Reverse Dynamic Impedance
Low-Frequency Noise
Temperature Coefficient
(Note 3)
Long-Term Drift
Thermal Hysteresis (Note 4)
SYMBOL
CONDITIONS
VR
TA = +25°C,
IR = 1.2µA
MAX6009A (0.2%)
MAX6009B (0.5%)
IRMIN
TC
VR change < 0.2% from VR at IR = 1.2µA
IR = 1.2µA to 200µA
IR = 200µA to 2mA
IR = 1.2µA to 2mA (Note 2)
IR = 1.2µA, f = 0.1Hz to 10Hz
IR = 1.2µA
MAX6009A
MAX6009B
1000h at TA = +25°C
MIN
2.9940
2.9850
TYP
3.000
3.000
0.5
75
150
200
MAX
3.0060
3.0150
1.0
1.7
2.7
2.2
30
75
UNITS
V
µA
mV
W
µVP-P
ppm/°C
ppm
ppm
Note 1: All devices are 100% production tested at TA = +25°C and are guaranteed by design for TA = TMIN to TMAX, as specified.
Note 2: This parameter is guaranteed by the “reverse breakdown change with current” test.
Note 3: TC is measured by the “box” method; i.e., (VMAX - VMIN)/(TMAX - TMIN).
Note 4: Thermal hysteresis is defined as the change in the +25°C output voltage after cycling the device from TMIN to TMAX.
Typical Operating Characteristics
(CL = 0.01µF, TA = +25°C, unless otherwise noted.)
TEMPERATURE DRIFT
0.5 IR = 1.2µA
0 VOUT = 2.5V
-0.5
-1.0
-1.5
-2.0
-2.5
-3.0
-50
0
50
100
TEMPERATURE (°C)
MAX6006
VOUT vs. CURRENT
2.5
1.5V
2.0
1.5
0
1.0
TA = +85°C TA = -40°C
0.5
0
0.001
TA = +25°C
0.01
0.1
1
10
REVERSE CURRENT (mA)
MAX6006
STARTUP
1.2µA
20ms/div
www.maximintegrated.com