datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

MC33166 查看數據表(PDF) - ON Semiconductor

零件编号
产品描述 (功能)
比赛名单
MC33166 Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MC34166, MC33166
ORDERING INFORMATION
Device
MC33166D2T
MC33166D2TG
MC33166D2TR4
MC33166D2TR4G
Operating
Temperature Range
Package
D2PAK − Surface Mount
D2PAK − Surface Mount
(Pb−Free)
D2PAK − Surface Mount
D2PAK − Surface Mount
(Pb−Free)
Shipping
50 Units/Rail
800 / Tape & Reel
MC33166T
MC33166TG
TA= −40° to +85°C
TO−220 − Straight Lead
TO−220 − Straight Lead
(Pb−Free)
MC33166TH
MC33166THG
MC33166TV
MC33166TVG
MC34166D2T
MC34166D2TG
MC34166D2TR4
MC34166D2TR4G
TO−220 − Horizontal Mount
TO−220 − Horizontal Mount
(Pb−Free)
TO−220 − Vertical Mount
TO−220 − Vertical Mount
(Pb−Free)
D2PAK − Surface Mount
D2PAK − Surface Mount
(Pb−Free)
D2PAK − Surface Mount
D2PAK − Surface Mount
(Pb−Free)
50 Units/Rail
800 / Tape & Reel
MC34166T
MC34166TG
MC34166TH
MC34166THG
TA= 0° to +70°C
TO−220 − Straight Lead
TO−220 − Straight Lead
(Pb−Free)
TO−220 − Horizontal Mount
TO−220 − Horizontal Mount
(Pb−Free)
50 Units/Rail
MC34166TV
TO−220 − Vertical Mount
MC34166TVG
TO−220 − Vertical Mount
(Pb−Free)
†For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging
Specifications Brochure, BRD8011/D.
MAXIMUM RATINGS
Rating
Power Supply Input Voltage
Switch Output Voltage Range
Voltage Feedback and Compensation Input Voltage Range
Power Dissipation
Case 314A, 314B and 314D (TA = +25°C)
Thermal Resistance, Junction−to−Ambient
Thermal Resistance, Junction−to−Case
Case 936A (D2PAK) (TA = +25°C)
Thermal Resistance, Junction−to−Ambient
Thermal Resistance, Junction−to−Case
Operating Junction Temperature
Operating Ambient Temperature (Note 2)
MC34166
MC33166
Symbol
VCC
VO(switch)
VFB, VComp
PD
qJA
qJC
PD
qJA
qJC
TJ
TA
Value
40
−1.5 to + Vin
−1.0 to + 7.0
Internally Limited
65
5.0
Internally Limited
70
5.0
+150
0 to + 70
− 40 to + 85
Unit
V
V
V
W
°C/W
°C/W
W
°C/W
°C/W
°C
°C
Storage Temperature Range
Tstg
− 65 to +150
°C
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
1. This device series contains ESD protection and exceeds the following tests:
Human Body Model 2000 V per MIL−STD−883, Method 3015.
Machine Model Method 200 V.
2. Tlow = 0°C for MC34166
= − 40°C for MC33166
Thigh = + 70°C for MC34166
= + 85°C for MC33166