Functional Description
14 MFO1
15 MFO2
16 LD
pin 14
2pF
MFO1
ESD
560Ω
IREF
VREF
Internal Charge
Pump Mode
& standby
VREF
MF02
2pF Pin15
ESD
pin 16
2pF
LD
ESD
Multifunction Output for the signals fRN ,
ΦV,, ΦVN , and port1.
–The signal fRN is the divided signal of the
reference frequency.
The L-time corresponds to 1/fRI respec-
tively
–In the port function the port 1 output sig-
nal is assigned to the information of the
programmed status. The output switches
with the rising edge of the EN-signal
The standby mode does not affect the
port function.
Multifunction I/O-Pin for the external ref-
erence current setting IREF and the signals
ΦRN and fVN ( in testmode).
–The signal fVN is the divided signal of FI-
input. The L-time corresponds to 1/fFI
respectively.
Output levels are not specified, the signal
should only be used for test purpose.
–In the internal charge pump mode the
reference current IREF at MFO2 deter-
mines the value of the PD-output current.
Lock Detector Output (open drain). Uni-
polar output of the phase detector in the
form of a pulse-width modulated signal.
The LD-pulse width corresponds to the
phase difference. In the locked state the
LD-signal is at H-level. For standby mode
see Standby Table.
Only for ABL status 11 no gating of ABL
impulse is performed.