AP501
PCS-band 4W HBT Amplifier Module
The Communications Edge TM
Product Information
Performance Graphs – Class B Configuration
The AP501 can be adjusted to operate at lower current biasing levels by modifying the R7 resistor for improved efficiency
performance. The configuration shown on this page has the AP501 operating with Icq = 250 mA (Icc = 400 mA @ 27 dBm).
Output L-C matching components have been added externally on the circuit to optimize the amplifier for ACPR performance at
this biasing configuration.
DNP
10μF
0
730
RF IN
DNP
DNP
0
DNP
DNP
100pF
.01μF
DNP
DNP
6 54 32 1
.01μF
100pF
2.2nH
DNP
RF OUT
R2
0.2pF
Notes:
1. Please note that for reliable operation, the evaluation board will have to
be mounted to a much larger heat sink during operation and in laboratory
environments to dissipate the power consumed by the device. The use of
a convection fan is also recommended in laboratory environments.
Details of the mounting holes used in the WJ heatsink are given on the
last page of this datasheet.
2. The area around the module underneath the PCB should not contain any
soldermask in order to maintain good RF grounding.
3. For proper and safe operation in the laboratory, the power-on sequencing
should be followed:
a. Connect RF In and Out
b. Connect the voltages and ground pins as shown in the circuit.
c. Apply the RF signal
d. Power down with the reverse sequence
Narrowband S-Parameters
+25 °C, Icq=250mA
31
0
30
-5
29
-10
S21
28
S11 -15
S22
27
-20
26
1930
1950
1970
Frequency (MHz)
-25
1990
ACPR vs. Channel Power
+25 °C, IS-95A, 9 Ch. Fwd, 1FA, fo=1960 MHz, Icq=250mA
-40
±885 kHz
±1.25 MHz
-50
PAE / Icc vs. Output Power
+25 °C, 1960 MHz, Icq=250mA
500
50%
Icc PAE
400
40%
300
30%
200
20%
100
10%
0
0%
24 25 26 27 28 29 30
Output Power (dBm)
ACPR vs. Channel Power
+25 °C, IS-95A, 9 Ch. Fwd, 7FA, fo=1935 MHz, Icq=250mA
-40
±885 kHz
±1.25 MHz
-50
OIP3 / IMD vs. Output Power
+25 °C, 1960 MHz, Icq=250mA
-20
55
-30
50
-40
45
-50
40
-60
-70
22
35
IMD
OIP3
30
24
26
28
30
Output Power / tone (dBm)
ACLR vs. Channel Power
+25 °C, 3GPP W-CDMA, Test Model 1+32 DPCH, 1960 MHz, Icq=250mA
-40
±5 MHz
±10 MHz
-50
-60
-60
-60
-70
25 26 27 28 29 30 31
Output Channel Power (dBm)
-70
18 19 20 21 22 23 24 25
Output Channel Power (dBm)
-70
20 21 22 23 24 25 26 27 28
Output Channel Power (dBm)
Specifications and information are subject to change without notice