5P49V5901 DATASHEET
Table 19:DC Electrical Characteristics for LVPECL (VDDO = 3.3V+5% or 2.5V+5%, TA = -40°C to
+85°C)
Symbol
Parameter
VOH
VOL
VSWING
Output Voltage HIGH, terminated through 50tied to VDD - 2 V
Output Voltage LOW, terminated through 50tied to VDD - 2 V
Peak-to-Peak Output Voltage Swing
Min
Typ
Max Unit
VDDO - 1.19
VDDO - 1.94
0.55
VDDO - 0.69 V
VDDO - 1.4 V
0.993
V
Table 20:Electrical Characteristics – DIF 0.7V HCSL Differential Outputs (VDDO = 3.3V±5%,
2.5V±5%, TA = -40°C to +85°C)
Symbol Parameter
Conditions
Min
Typ
Max Units Notes
dV/dt Slew Rate
Scope averaging on
1
4
V/ns 1,2,3
ΔdV/dt
VHIGH
VLOW
Slew Rate
Voltage High
Voltage Low
Scope averaging on
Statistical measurement on single-ended
signal using oscilloscope math function
660
(Scope averaging ON)
-150
20
%
1,2,3
850
mV 1,6,7
150
mV
1,6
VMAX Maximum Voltage
VMIN Minimum Voltage
Measurement on single-ended signal using
absolute value (Scope averaging off)
-300
1150
mV
1
mV
1
VSWING Voltage Swing
Scope averaging off
300
mV 1,2,6
VCROSS Crossing Voltage Value Scope averaging off
250
550
mV 1,4,6
ΔVCROSS Crossing Voltage variation Scope averaging off
140
mV
1,5
1. Guaranteed by design and characterization. Not 100% tested in production
2. Measured from differential waveform.
3. Slew rate is measured through the VSWING voltage range centered around differential 0V. This results in a +/-150mV window around
differential 0V.
4. VCROSS is defined as voltage where Clock = Clock# measured on a component test board and only applies to the differential rising edge
(i.e. Clock rising and Clock# falling).
5. The total variation of all VCROSS measurements in any particular system. Note that this is a subset of VCROSS min/max (VCROSS absolute)
allowed. The intent is to limit VCROSS induced modulation by setting VCROSS to be smaller than VCROSS absolute.
6. Measured from single-ended waveform.
7. Measured with scope averaging off, using statistics function. Variation is difference between min. and max.
PROGRAMMABLE CLOCK GENERATOR