M62364FP
AC Characteristics
(VDD = 5 V ± 10%, VDD VIN, GND, VDAref = 0 V, Ta = –20 to +85°C, unless otherwise noted.)
Limits
Item
Symbol Min
Typ
Max Unit
Conditions
Clock "L" pulse width
tCKL
200
ns
Clock "H" pulse width
tCKH
200
ns
Clock rise time
tCR
200
ns
Clock fall time
tCF
200
ns
Data setup time
tDCH
60
ns
Data hold time
tCHD
100
ns
LD setup time
tCHL
200
ns
LD hold time
tLDC
100
ns
LD "H" pulse duration time tLDH
100
ns
Data output delay time
tDO
D/A output setting time
tLDD
70
350
ns CL = 100 pF
300
μs CL 100 pF, VAO: 0.1 2.6 V
This time until the output becomes
the final value of 1/2 LSB
Timing Chart
CLK
tCR
tCKH
tCF
tCKL
DI
LD
D/A output
Do output
tDCH
tCHD
tCHL
tDO
tLDH
tLDC
tLDD
REJ03D0875-0300 Rev.3.00 Mar 25, 2008
Page 4 of 7