STATIC ELECTRICAL RATINGS (Tcase = 25°C unless otherwise stated)
Characteristic
Test Conditions
BVDSS
IDSS
IGSS
VGS(TH)
ID(ON)
RDS(ON)
Drain Source Breakdown Voltage
Zero Gate Voltage Drain Current
(VGS = 0V)
Gate Source Leakage Current
Gate Threshold Voltage
On State Drain Current 2
Drain Source On State Resistance 2
VGS = 0V , ID = 250µA
VDS = VDSS
VDS = 0.8VDSS , TC = 125°C
VGS = ±30V , VDS = 0V
VDS = VGS , ID = 1.0mA
VDS > ID(ON) x RDS(ON) Max
VGS = 10V
VGS = 10V , ID = 0.5 ID [Cont.]
Min.
1000
2
3.6
Typ.
Max. Unit
V
250
µA
1000
±100 nA
4V
A
4.00 9
DYNAMIC CHARACTERISTICS
Characteristic
CDC
Ciss
Coss
Crss
Qg
Qgs
Qgd
td(on)
tr
td(off)
tf
Drain to Case Capacitance
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Total Gate Charge
Gate Source Charge
Gate Drain (Miller) Charge
Turnon Delay Time
Rise Time
Turn-off Delay Time
Fall Time
Test Conditions
f = 1MHz
VGS = 0V
VDS = 25V
f = 1MHz
VGS = 10V
VDD = 0.5 VDSS
ID = ID [Cont.] @ 25°C
VGS = 10V
VDD = 0.5 VDSS
ID = ID [Cont.] @ 25°C
RG = 1.89
Min.
Typ.
15
805
115
37
35
4.3
18
10
12
33
16
Max. Unit
22 pF
950
160 pF
60
55
7 nC
27
20
24 ns
50
32
SOURCE DRAIN DIODE RATINGS AND CHARACTERISTICS
Characteristic
Test Conditions
IS
Continuous Source Current (Body Diode)
ISM
Pulsed Source Current1
(Body Diode)
VSD
Diode Forward Voltage2
VGS = 0V , IS = ID [Cont.]
trr
Reverse Recovery Time
IS = ID [Cont.] , dls / dt = 100A/µs
Qrr
Reverse Recovery Charge IS = ID [Cont.] , dls / dt = 100A/µs
Min.
Typ.
290
1.65
Max. Unit
3.6
A
14.4
1.3 V
580 ns
3.3 µC
SAFE OPERATING AREA CHARACTERISTICS
Characteristic
SOA1
SOA2
ILM
Safe Operating Area
VDS = 0.4VDSS , IDS = PD / 0.4VDSS , t = 1 Sec.
Safe Operating Area
IDS = ID [Cont.] , VDS = PD / ID [Cont.] , t = 1 Sec.
Inductive Current Clamped
1) Repetitive Rating: Pulse Width limited by maximum junction temperature.
2) Pulse Test: Pulse Width < 380µS , Duty Cycle < 2%
Min.
125
125
3.6
Typ.
Max. Unit
W
A
CAUTION Electrostatic Sensitive Devices. Anti-Static Procedures Must Be Followed.