datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

LT8302HS8E-3-WPBF 查看數據表(PDF) - Analog Devices

零件编号
产品描述 (功能)
比赛名单
LT8302HS8E-3-WPBF Datasheet PDF : 26 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
LT8302/LT8302-3
APPLICATIONS INFORMATION
Step 6: Select the RREF and RFB resistors.
Use the following equation to calculate the starting values
for RREF and RFB:
( ) ( ) RFB
=
RREF
NPS
VOUT
VREF
+
VF
TO
RREF = 10k
Example:
RFB
=
10k
3 • (5V +
1.00V
0.3V)
=
159k
For 1% standard values, a 158k resistor is chosen.
Step 7: Adjust RFB resistor based on output voltage.
Build and power up the application with application com-
ponents and measure the regulated output voltage. Adjust
RFB resistor based on the measured output voltage:
RFB(NEW)
=
VOUT
VOUT(MEASURED)
• RFB
Example:
RFB
=
5V
5.14V
158k
=
154k
Step 8: Select RTC resistor based on output voltage tem-
perature variation.
Measure output voltage in a controlled temperature envi-
ronment like an oven to determine the output temperature
coefficient. Measure output voltage at a consistent load
current and input voltage, across the operating tempera-
ture range.
Calculate the temperature coefficient of VF:
(δVF
/δT)
=
VOUT
(T1)
T1–
VOUT
T2
(T2)
RTC
=
3.35mV/°C
(δVF/δT)
⎛⎝⎜ NRPFBS
Example:
(δVF
/δT)
=
5.189V –
100°C –
5.041V
(0°C)
=
1.48mV
/
°C
RTC
=
3.35mV/°C
1.48mV/°C
⎝⎜
154
3
⎠⎟
=
115k
Step 9: Select the EN/UVLO resistors.
Determine the amount of hysteresis required and calcu-
late R1 resistor value:
VIN(HYS) = 2.5µA • R1
Example:
Choose 2V of hysteresis, R1 = 806k
Determine the UVLO thresholds and calculate R2 resistor
value:
VIN(UVLO+)
=
1.228V
(R1+
R2
R2)
+
2.5µA
R1
Example:
Set VIN UVLO rising threshold to 7.5V:
R2 = 232k
VIN(UVLO+) = 7.5V
VIN(UNLO) = 5.5V
Step 10: Ensure minimum load.
The theoretical minimum load can be approximately esti-
mated as:
ILOAD(MIN)
=
9µH (1.04A )2
2 5V
12.7kHz
=12.4mA
Remember to check the minimum load requirement in
real application. The minimum load occurs at the point
where the output voltage begins to climb up as the con-
verter delivers more energy than what is consumed at
the output. The real minimum load for this application is
about 10mA. In this example, a 500Ω resistor is selected
as the minimum load.
Rev. G
20
For more information www.analog.com

Share Link: 