XC835/836
Electrical Parameters
3.3.3 Oscillator Timing and Wake-up Timing
Table 19 provides the characteristics of the power-on reset, PLL and wake-up timings in
the XC835/836.
Table 19 Power-On Reset Wake-up Timing1) (Operating Conditions apply)
Parameter
Symbol
Limit Values Unit Test Conditions
Min. Typ. Max.
48 MHz Oscillator
start-up time
t48MOSCST CC –
–
13 µs
75 KHz Oscillator start- t75KOSCST CC –
–
800 µs
up time
32 KHz external
oscillator start-up
time2)
t32KOSCST CC –
–
1
s
Flash initialization time tFINT
CC – 160 –
µs
1) Not subject to production test, verified by design/characterisation.
2) The external circuitry has to be optimized by the user and checked for negative resistance as recommended
and specified by the crystal supplier.
Data Sheet
40