The equation of fitted 2nd order polynome curve for sensitivity compensation is:
Scorr  0.00011*T 2 0.0022*T 0.0408
Where:
Scorr:
T
2nd order polynome fitted to average sensitivity temperature dependency curve
temperature in °C
The calculated compensation curve can be used to compensate the temperature dependency of
the SCA100T sensitivity by using following equation:
SENScomp SENS *(1Scorr /100)
Where:
SENScomp temperature compensated sensitivity
SENS
Nominal sensitivity (4V/g SCA100T-D01, 2V/g SCA100T-D02)
The typical offset and sensitivity temperature dependency after external compensation is shown in
the pictures below.
Temperature dependency of externally compensated
SCA100T offset
1
0.8
0.6
0.4
0.2
0
-0.2
-0.4
-0.6
-0.8
-1
-40 -20
0
20
40 60 80 100 120
Temp [°C]
Average
+3 sigma
-3 sigma
Figure 6. The temperature dependency of an externally compensated SCA100T offset
Temperature dependency of externally compensated
SCA100T sensitivity
1
0.8
0.6
0.4
0.2
0
-0.2
-0.4
-0.6
-0.8
-1
-40 -20
0
20
40
60
80 100 120
Temp [°C]
Average
+3 sigma
-3 sigma
Figure 7. The temperature dependency of an externally compensated SCA100T sensitivity