AD8151
RESET INPUT
DISABLING
OUT[0:16][N:P]
OUTPUTS
tTOD
tTW
Figure 7. Asynchronous Reset
Table VII. Asynchronous Reset
Symbol
tTOD
tTW
Parameter
Disable Time
Output Disable from Reset
Width of Reset Pulse
Conditions
TA = 25°C
VDD = 5 V
VCC = 3.3 V
Min Typ Max Unit
25
30
ns
15
ns
Control Interface Programming Example
The following conservative pattern connects all outputs to input number 7, except output 16 which is connected to input number 32.
The vector clock period, T0 is 15 ns. It is possible to accelerate the execution of this pattern by deleting vectors 1, 4, 7, and 9.
Vector No.
0
1
2
3
4
5
6
7
8
9
10
RESET CS
0
1
1
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
1
Table VIII. Basic Test Pattern
WE
RE
UPDATE A[4:0]
1
1
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
1
0
1
1
1
1
1
1
1
0
1
1
1
1
1
1
xxxxx
xxxxx
10001
10001
10001
10000
10000
10000
xxxxx
xxxxx
xxxxx
D[6:0]
xxxxxxx
xxxxxxx
1000111
1000111
1000111
1100000
1100000
1100000
xxxxxxx
xxxxxxx
xxxxxxx
Comments
Disable All Outputs
All Outputs to Input #07
Write to First Rank
Output #16 to Input #32
Write to First Rank
Transfer to Second Rank
Disable Interface
REV. 0